ARCHOS 97 Carbon custom firmware with root and 2 Gb space for apps, works with Arnova 9 G3 too !

22

Désolé, cet article est seulement disponible en Anglais Américain.

22 COMMENTS

  1. I did it, thank you so much! After some issue with the drivers I got the new firmware on my tablet ARCHOR 97 CARBON. I am so happy because now I have more space on it and it seems to go faster. The battery indicator shows constantly 100% but this is no problem for me 🙂 I only needed the extra space…

  2. Has anyone any ideas on why when I try to install from SD in CWM it first says e-signature error then asks if I still want to install un-trusted ZIp it aborts. no matter how many attempts it just aborts, is file corrupt or fake?
    I cannot use rockchip method for two reasons;
    1. Micro USB socket damaged – main usb will not connect to PC.
    2. Rockchip does not see any device – I tried to see if any tablet would connect, nothing.

    Help please 512MB of apps is not worth it.

  3. Thanks. Installed this last night and works rather well. The only difficult I had was to understand how to get to the flash mode for the Elements Carbon 97 model. Essentially, it was a case of having the USB cable plugged in, the tablet switched on and then selecting the HOME and POWER button simultaneously. After a few seconds, the screen goes blank (black) (almost looking like its been switched off), but that was not the case and essentially that was when it had entered flash mode.

    Gr8 work.

  4. i can’t get into recovery mood. as the picture told, « insert a paperclip in the Reset pinhole of the tablet and press the Home button », but all i got is just restarting. can you describe more details about it? my 97 carbon’s version is 4.0.3.

    thank you very much!

    • I didn’t know my 97 was entering flash mode, there are no visual signs, the screen doesn’t change, it just stays black like it’s not on.

      I realised it was going into flash mode when it was connected to my PC via USB and I followed the instructions, I got the ‘found new hardware’ noise. Not the message mind. I needed to go into Device Manager where there was an unknown device and use the drivers in the Rockchip bundle to recognise the unknown device. Then the Rockchip flash tool would see it, and I could update the firmware.
      So, plug your device into your PC with a USB cable, insert a paperclip in the Reset pinhole of the tablet and press the Home button, wait till you hear the found new hardware noise, check Device Manager, etc etc and hopefully you’ll get there. It sounds like you definitely need to reflash the device anyway.

  5. This firmware seems reasonably stable on a 9 G3 but it has hung a few times and took about three reboots and two sets of calibration before it finally settled down…

    However, I agree with Marcojedi, the battery indicator no longer works and constantly shows 100%. I have also tried a Battery Indicator tool from Google Play and this does the same thing so I’m guessing there must be a hardware incompatibility in the firmware, between the Carbon and the G3 ?

    Any ideas how to fix this?

  6. Hello,

    I have to fall in love my arnova 9G3 with the custom firmware Arnova97. Everything is OK except that the capacity battery does not change any more. I do not know any more the load of the tablet. Have you a solution.

    Cordially.

    Marc